F&H Consultants, P.C.
Engineers & Construction Consultants
Glenarden Community Center
Discipline:
Electrical Engineering
Glenarden, Maryland
Square Footage:
32,000 sq. ft.

Provided electrical engineering services for the design of the security system, telephone/data and public address system for addition and renovation to an existing community center totaling 32,000 sq. ft.
A security system was designed for the renovation and new addition areas. Security System devices included the following:
Pan Tilt Zoom (PTZ) Security Cameras
Dome type Security Cameras
Motion Detectors
Card Readers
Piezo Sirens
Intrusion/Card Acess Panel
Keypad & Reader
Door Contacts
Provided a security system riser diagram indicating wiring and devices such as Ethernet switch, UPS, LAN Switch, DVR, Intrusion/Card Access Panel, Telephone router, etc.
Designed a multi-zone public address system. The zones were divided into the following areas:
Gymnasium
Offices & Hallways
Multi-Purpose Room # 1
Multi-Purpose Room # 2
Arts & Crafts Room
Exercise Room
Pool
Game Room
The system was designed to accept inputs from multiple sources such as microphones located in reception desk, gym, multi-purpose rooms and CD/MP3 Player.
Provided a floor plan showing the location of public address system devices. Coordinated the location of speakers with the proposed lighting fixtures and air distribution devices.
Provided a riser diagram showing the public address system equipment rack which houses the amplifiers, logic box, digital signal processor, and input sources.
Three different types of speakers were provided throughout the community center as follows:
Recessed speakers for drop ceilings
Pendant mounted speakers for open ceilings
Horn type loudspeakers for gymnasium